Filter Results By:

Products

Applications

Manufacturers

Alternating Current

Current Alternates direction of flow cyclically. AKA: AC

See Also: Current, Direct Current, AC


Showing results: 46 - 60 of 288 items found.

  • Environmental Chamber

    Wewon Environmental Chambers Co, Ltd.

    The environmental chamber for conditioning of samples prior to testing, It also can be used for a variety of materials of high – low temperature alternating test. The test for temperature, humidity, time can be programmed. Provides conditions of temperature from -70 degree to +180 degree and of humidity form 10% to 98%.environmental chamber ● The ideal simulation environmental chamber for all heat and cold testing between -70 ºC and 180 ºC temperature range.● Well suited for reliability testing based on current test standard in the temperature range of -70 °C to 180 °C & 10% to 98% RH.● This design SUS environmental chamber meet all requirements for extreme testing and low temperature alternating climate profiles from -70 °C -180 °C with humidity

  • Inductive Sensors

    Bernstein AG

    In general, inductive proximity switches consist of four basic elements: a coil, an oscillator, a threshold switch and an output stage with short-circuit protection.The oscillator generates a high frequency, electromagnetic alternating field which is emitted from the active face of the coil.Eddy currents are induced in a metal object that enters this field. These eddy currents draw energy from both the electromagnetic field and from the oscillator which is consequently attenuated.The more energy taken the closer the metal object moves towards the active face. The threshold switch switches on the output stage at a defined attenuation value.In proximity switches with a DC voltage supply, this switch is designed as an NPN transistor which switches the connected load to the negative pole or as a PNP transistor which switches the load to the positive pole. The output stage is a thyristor or a triac in AC voltage switches.

  • Static Measurement

    Nex Flow Air Products Corp.

    electrofield meter is a small hand-held field strength meter with a digital display for measuring electrostatic charges in Volts. It perfectly combines easy operation with an accurate measuring technique. The Static Meter measures charges according to the field influence principle C: The influenced charges, caused by the electrical field, generate an alternating current proportional to the electrical field strength. The selective amplifier converts this value into the corresponding field strength or electrical potential – without withdrawing energy from the electric field over the averaged time.

  • High Voltage Power Supplies

    Guth GmbH

    The mains voltage (230V / 3 x 400V) is transformed, rectified and filtered by the HN series. The direct current output voltage is tuned by a variable transformer or regulated by a thyristor controller. With the HS and HV series the rectified mains voltage is supplied to a frequency converter, which produces a mid-frequency square wave voltage. This transformed, rectified and filtered alternating current produces the desired voltage as output, which is regulated by means of frequency variation or pulse width modulation. The equipment in the HV series supply, in addition to the high voltage output, up to 3 auxiliary outputs which can be used to supply e.g. heating, grid voltage or surge voltage.

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • DC Power Supplies

    Scientech Technologies Pvt. Ltd.

    Power Supply is the most indispensable component of any electronic laboratory. A reliable, most accurate, fully specified, guaranteed and an efficient Power Supply Equipment are thus manufactured on a large scale by Scientech Technologies which has robust output protection and fault detection capabilities. DC Power Supplies with Different specifications of Voltage and Current are being manufactured for various Applications. The DC power supply converts the conventional 110 V or 220 V alternating voltage into continuous pulsating DC voltage (+3.3 V, +5 V, +12 V and -12V) used by various electronic components. A DC Power Supply also regulates the voltage to eliminate spikes and surges common in most electrical systems.

  • Power Analyzers

    PCE Instruments

    At PCE Instruments you will find a power quality analyzer to measure the power in W, kWh or to analyze and measure harmonics. This power analyzer is a multi-function power analyzer device that measure precisely direct current, alternating current, AC-voltage, DC-voltage the intensity of DC or AC, phase rotation and idle, apparent and effective power. The reading of AC power is considered the real value and has a maximum range of 6000 Watts. While a reading is being taken, the polarity changes automatically, if negative values are taken then a minus sign will appear on the device display.Nowadays, power quality analyzers have many features such as, insulated current input, measurement of harmonics, AC and DC current measurement, AC and DC voltage measurement, frequency measurement, phase rotation measurement and idle, apparent and effective power measurement. All this data can also be logged and analyzed with the delivered PC-Software. Power analyzers of the type PCE PA 6000 can determine the energy in single-phase systems.Power quality analyzers of type PCE-GPA 62 allow the energy measurement in symmetrically loaded three-phase systems. Power analyzers of type PCE-PA 8000, PCE-360 and PCE-830 support professional power and energy measurements in single and three-phase systems.Apart from being used as energy-measuring devices, power analyzers like the PCE-830 can also be used for network analysis and the determination of harmonics and phase rotation. On our website you will find other power analyzers used in the field of electronics.

  • High End Current Sensors

    Danisense a/s

    AC and DC currents with an accuracy down to 1ppm. Our standard products offers the following features: Automotive current sensors. Extended temperature current sensor - 85 deg Celcius. AC current sensor - DC current sensor.

  • Transducers

    Rishabh Instruments Pvt. Ltd.,

    Current Transformers With Transducer for the measurement of AC current. A very reliable, efficient and robust current transformer for measurement of AC current. It provides 4 to 20 mA or 0 to 20mA DC output.

  • Current Transformers

    Rishabh Instruments Pvt. Ltd.,

    Rish Nano CT is a very reliable, efficient and robust current transformer for measurement of AC current. It provides 100 mA AC output. It can be used in Circuit breakers. Earth Leakage Protection.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • Ionization bars

    Wolfgang Warmbier GmbH & Co. KG

    Suitable for down-stream applications ie "laminar airflow boxes"Air assistance for various applicationsComplies with IEC 61340-5-1 Ed. 1.0 (2007-08)Pulsed AC high voltage IonizationEach tip emits positive and negative ionsSelf-balancing ± 30VControl input and alarm output connectorPower supply 230V / AC via controllerOne controller is suitable for two ion barsAdjustments on controller sideEasy emitter replacement

  • Single Phase AC Power Source

    APS51 Series - Twintex Electronics Co., Ltd

    ★ Full range adjustable output: Low 1-150V, High 150.1~300V, resolution 0.1V★ Output frequency: 45-250Hz★ Fast output key for 110V/220V and 50Hz/60Hz★ Panel lock function★ 3 sets memories for voltage and frequency settings★ Unlimited rotary knob for voltage and frequency adjustment, minimum step 0.001★ Strong overload capacity, overload 300% within 2s★ Withstand transient current 1.5 times of rated current within 0.1s★ Response time less than 20ms for 100% load and unload★ 5 digits high accuracy LED display for voltage, current, frequency, active power, power factor★ With soft-start function, set voltage rise time (0~99.999s), avoid damage by surge current during load start-up★ Over load, over current, over temperature and short circuit protections★ RS232 interface

  • Bench Multimeters

    TM-8155+ - Twintex Electronics Co., Ltd

    ★ Large LCD, 80000 count Dual-display, Analog bar 21 sets.★ 50 measuring functions, with basic DCV, ACV, DCA, ACA, Ω, CAP, Hz, TEMP, diode and Continuity measuring function, etc.★ 18 types of frequency, frequency up to 8MHz, 1800 waveform outputs, 1%~99% duty cycle★ Simultaneous measure (AC+DC), (AC+Hz), (DC+dBm), (dBm+Hz), (Hz+Duty), (℃+℉)★ Auto data update and refresh, auto data hold, auto peak hold.★ 36-hour dynamic record: MAG, MIN, AVG, MAX-MIN (RELΔ), (REL%), setting upper & lower limit, timing measurement★ AC measuring adopts highly accurate true RMS measurement, with testing frequency bandwidth and AC+DC measuring★ RS-232 interface

Get Help